  Datasheet File OCR Text:
  ml100.200 miniline 24v 4.2a, t wo -p hase i nput ml100.200 rev 1.0-en / all parameters are specified at 24v, 4.2a, 400vac and 25c ambient unless otherwise noted. www.pulspower.com phone + 49 89 9278 0 germany 1/2 p ower s upply 2ac 380-480v 2 phase input no neutral wire required input fuse included efficiency up to 90.0% full output power between -10c and +60c quick-connect spring-clamp terminals 3 year warranty g eneral d escription s hort - form d ata output voltage dc 24v adjustment range 24-28v guaranteed output current 4.2-3.6a output power 100w output ripple < 50mvpp 20hz to 20mhz input voltage 2ac 380-480v 15% mains frequency 50-60hz 6% ac input current typ. 0.46 / 0.4a at 400 / 480vac power factor typ. 0.6 / 0.55 at 400 / 480vac ac inrush current typ. 36 / 45a at 400 / 480vac hold-up time typ. 48 / 85ms at 400 / 480vac dc input consult puls efficiency 89.5 / 89.0% at 400 / 480vac losses 11.7 / 12.3w at 400 / 480vac temperature range -10c to +70c operational -40c to +85c storage, transport derating 2.5 w/c +60 to +70c humidity < 95% r.h. iec 60068-2-30 do not energize while condensation is present vibration 2g (2 hours/axis) iec 60068-2-6 shock 30g 6ms, 20g 11ms iec 60068-2-27 the ml100.200 is a simple and cost effective approach to convert the ac voltage of a typical three phase system into a re gulated dc voltage. it only requires two phases and thereby saves terminal space, terminal cost, wire s, fuses and installation time. the ml100.200 is very compact, high efficient and easy to use. the input is internally protected, which makes external fuses unnecessary in many cases. weighing only 360g, it is a lightweight compared to the 50/60hz control tr ansformers, which are commonly used for low-power control voltages where a neutral wire is not available. high immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. l1 l2 l3 pe ml100.200 l1 + + - - dc ok l2 24- 28v dimensions 72.5x75x103mm wxhxd o rder n umbers m arkings power supply ml100.200 24-28v power supply accessory mly02.100 decoupling module ind. cont. eq. 18wm listed ul 508 ul 60950-1, emc, lvd
ml100.200 miniline 24v 4.2a, t wo -p hase i nput ml100.200 rev 1.0-en / all parameters are specified at 24v, 4.2a, 400vac and 25c ambient unless otherwise noted. www.pulspower.com phone + 49 89 9278 0 germany 2/2 o utput output voltage nom dc 24v adjustment range min 24v-28v factory set typ 24.5v output current nom 4.2a at 24v, 3.6a at 28v line regulation max 20mv 323?552vac load regulation max 240mv static regulation serial use allowed parallel use allowed return voltage max 35v ovp typ 34v max 39v output voltage vs. output current, typ. output voltage 0 024 4 8 12 28v 16 20 24 8a 5 3 1 67 adjustment range output current output current vs. ambient temperature allowable output current at 24v 0 -10 0 20 40 70c 1 2 3 4 5a 60 ambient temperature ambient temp. is defined 2cm below the unit s afety and p rotection input / output insulati on selv iec/en 60950-1 pelv en 60204-1 3000vac 2s type test degree of pollution 2 en 50178 degree of protection ip 20 en/iec 60529 class of protection i pe required over-voltage category iii en 50178 internal inpu t fuse t3a15 in l1, not accessible temperature protection not included t erminals and w iring type bi-stable, quick-connect spring clamp terminals. shipped in open position. solid wire 0.3-2.5mm 2 stranded wire 0.3-2.5mm 2 awg awg 26-12 stripping length 6mm / 0.25inch ferrules allowed, but not required emc emc immunity en 61000-6-1, en 61000-6-2 emc emission en61000-6-3, en 61000-6-4 en 55011, en 55022, fcc-15 harmonic input current en61000-3-2 (pfc) flicker en61000-3-3 a pprovals ul 508 industrial control equipment ul 60950-1 information technology equipment f ulfilled s tandards en 61558-2-17 safety of power transformers en/iec 60204-1 safety of electrical equip. of machines en/iec 60950-1 information technology equipment en/iec 61131-2 programmable controllers en 50178 electronic equip. power installations d imensions and w eight use 35mm din-rails according to en 60715 or en 50022 with a height of 7.5 or 15mm. the din-ra il height must be added to the depth (103mm) to calculate the total required installation depth. weight max 360g 0.79lb the power supply shall only be installed and put into operation by qualified personnel. this power supply is designed for insta llation in an enclosure and is intended for the general use, such as in industrial con trol, office, communication, and instrumentation equipment. do no t use this device in aircraft, trains and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten h uman life. the information presented in this document is believed to be accurate and reliable and may change without notice.


▲Up To Search▲   

 
Price & Availability of ML100200

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X